You are viewing a prototype of the proposed aldohomes.ca expansion. Nothing here is live yet.
Home › Portfolio › Load-Bearing Wall Removal: Two-Storey Homes › 10th Line W

Load-Bearing Wall Removal in Mississauga: 10th Line W

The 10th Line W, Mississauga project required the removal of the load-bearing wall separating the dining and living rooms, but the structural conditions made this far more complex than a standard main-floor opening. The breakfast area on the main floor did not continue with an equivalent space on the second floor, and the exterior wall above, made of a cinder-block wall with an exterior brick envelope, was offset from the foundation.

Load-Bearing Wall Removal in Mississauga: 10th Line W

Project details

Location10th Line W, Mississauga
ProjectComplex Load-Bearing Wall Removal with Steel-to-Steel Beam Integration
Photos13
How we do this work

Project gallery

Load-Bearing Wall Removal in Mississauga: 10th Line W, photo 1Load-Bearing Wall Removal in Mississauga: 10th Line W, photo 2Load-Bearing Wall Removal in Mississauga: 10th Line W, photo 3Load-Bearing Wall Removal in Mississauga: 10th Line W, photo 4Load-Bearing Wall Removal in Mississauga: 10th Line W, photo 5Load-Bearing Wall Removal in Mississauga: 10th Line W, photo 6Load-Bearing Wall Removal in Mississauga: 10th Line W, photo 7Load-Bearing Wall Removal in Mississauga: 10th Line W, photo 8Load-Bearing Wall Removal in Mississauga: 10th Line W, photo 9Load-Bearing Wall Removal in Mississauga: 10th Line W, photo 10Load-Bearing Wall Removal in Mississauga: 10th Line W, photo 11Load-Bearing Wall Removal in Mississauga: 10th Line W, photo 12Load-Bearing Wall Removal in Mississauga: 10th Line W, photo 13

The 10th Line W, Mississauga project required the removal of the load-bearing wall separating the dining and living rooms, but the structural conditions made this far more complex than a standard main-floor opening. The breakfast area on the main floor did not continue with an equivalent space on the second floor, and the exterior wall above, made of a cinder-block wall with an exterior brick envelope, was offset from the foundation. Even more challenging, that offset exterior wall was sitting on an existing steel beam supported by a steel post hidden inside the wall we needed to remove. This created a unique engineering scenario where the new beam had to safely take over the load path of the existing structural steel.

The structural design called for a 20-ft W8 steel beam, weighing approximately 2,000 lb, paired with a custom-fabricated flange engineered to capture and support the existing beam. The implementation challenge was significant: we had to remove the original steel post and seamlessly connect the existing beam to the new one, all while that existing beam was carrying the full weight of the cinder-block exterior wall on the second floor. With precise shoring, careful sequencing, and a highly coordinated installation, the transition was executed flawlessly. As the project photos show, every risk was anticipated, accounted for, and fully mitigated.

This project is a strong example of the type of technical, detail-driven structural work we excel at, complex load paths, steel-to-steel integrations, and high-risk conditions requiring exact execution. As we often say: the more challenging the project, the better suited we are to handle it.

If you’re planning a main-floor renovation involving load-bearing wall removal, steel beam installation, or complex structural transitions, we’d be happy to help. We specialize in engineered solutions, permit-ready structural design, and safe, efficient implementation across Mississauga and the GTA.

More projects in Mississauga

← All load-bearing wall removal: two-storey homes projects Load-Bearing Wall Removal, explained →

Want this for your home?

Free assessment. Pick a time and we call you at the slot you choose.

Book a Free Assessment